MJC cartridge dust collector
Reverse jet tubular bag dust collectors for many applications that generate light to heavy volumes of any dust
Suitable for many different applications that generate light to heavy volumes of any dustThe MJC range of reverse jet tubular bag dust collectors was developed for continuous operation in industrial process filtration and dust collection applications; incorporating patented Nederman UniClean cartridge technology for maximum cleaning efficiency and extended life. Air Volume Range: 1.700 to 68.000 m3/hr (1,000 to 40,000 CFM) Cleaning controller type NF8HD250 in IP65 enclosure, supply voltage 230/220/110V.Key features: Standard filter range from 48 to 739m2 (517 to 7,955 ft2); larger units possible Typical airflow volumes up to 60.000m3/h (35,340 CFM), or more, subject top application Robust weatherproof welded steel construction Space saving integral fans from 0.75 to 18.5kW (1 to 25hp) Independently tested with ATEX compliant features for St1, St2 and St3 dusts Integral pre-separation chamber, cross flow / down flow inlet air pattern Wide range of discharge and waste handling options Typical dust control and process applications:
-
Suitable for many different applications that generate light to heavy volumes of any dust
The MJC range of reverse jet tubular bag dust collectors was developed for continuous operation in industrial process filtration and dust collection applications; incorporating patented Nederman UniClean cartridge technology for maximum cleaning efficiency and extended life.
Air Volume Range: 1.700 to 68.000 m3/hr (1,000 to 40,000 CFM)
Cleaning controller type NF8HD250 in IP65 enclosure, supply voltage 230/220/110V.
Key features:
Standard filter range from 48 to 739m2 (517 to 7,955 ft2); larger units possible
Typical airflow volumes up to 60.000m3/h (35,340 CFM), or more, subject top application
Robust weatherproof welded steel construction
Space saving integral fans from 0.75 to 18.5kW (1 to 25hp)
Independently tested with ATEX compliant features for St1, St2 and St3 dusts
Integral pre-separation chamber, cross flow / down flow inlet air pattern
Wide range of discharge and waste handling options
Typical dust control and process applications:
-
Shot, sand and bead blasting
-
Shot, sand and bead blasting
-
Welding and cutting – laser, plasma, arc
-
Chemical, plastics and pharmaceutical powders
Certifications |
CE, EX |
Standard |
2014/34/EC, 2004/108/EC, 2006/95/EC, EN 13463-1, EN 60204-1 |
Compressed air consumption |
-8,0 to 5,5 |
Installation |
Indoor, Outdoor |
Suitable for combustible dust |
Yes |
Filter cleaning method |
Pulse jet |
Application |
Dust, Grit, Fumes |
Dustbin volume (l) |
75 |
Filter Area (m²) |
48 to 739 |
Capacity (max airflow m3/h) |
190000 |
Operating Temperature |
-10 to 80 Deg. C. |
Filter type |
Cartridge |
Filter material |
Polyester |
Number of filter elements
16
Note
Unit has built-in pre-separation chamber at rear
Number of filter elements
20
Note
Unit has built-in pre-separation chamber at rear
Number of filter elements
24
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
32
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
40
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
48
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
56
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
64
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
72
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
9
Note
Unit has built-in pre-separation chamber at rear
Number of filter elements
12
Note
Unit has built-in pre-separation chamber at rear
Number of filter elements
16
Note
Unit has built-in pre-separation chamber at rear
Number of filter elements
20
Note
Unit has built-in pre-separation chamber at rear
Number of filter elements
24
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
32
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
40
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
48
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
56
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
64
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
72
Note
Unit has built-in pre-separation chamber at side, left or right
Number of filter elements
80
Number of filter elements
88
Note
Unit has built-in pre-separation chamber in the centre
Number of filter elements
96
Note
Unit has built-in pre-separation chamber in the centre
Number of filter elements
104
Note
Unit has built-in pre-separation chamber in the centre
Number of filter elements
112
Note