Explosion Isolation Flap Valve CARZ

Explosion Isolation Flap Valve CARZ - protective system.

Explosion Isolation Flap Valve type CARZ is design as explosion pressure resistance equipment, which is able to prevent a transmission of dangerous effects of explosion pressure wave and flames front to upstream areas.

Description

Welded construction in RAL 5009 blue painted steel plate or stainless steel with strong rubber seal, which is available upon request.

Function

During air flow generated by main fan, the Flap plate is open. In case of an explosion in the downstream equipment (e.g. dust collector) a pressure wave will force to close the Flap plate and lock in position. Large opening angle ensure low pressure drop. When Flap plate is closed it makes an effective barrier against approaching flame front. This prevent the explosion from being transmitted to upstream work areas.

  • Independently tested according to current standards and regulations
  • Compliant with most international dust explosion protection codes (ATEX and NFPA68)
  • Widest range of sizes, applications and filter system configurations on the market (incl. approval for positive and negative pressure systems)
  • Manufactured fully by Nederman under certified quality assurance system, ensuring highest level of quality and reliability

Technical data
Certifications CE, EX
Material Welded carbon steel, painted RAL5009
Operating temperature range -20°C - +70°C (Min 0 F Max 160 F)
Ambient temperature range -20°C - +60°C (Min 0 F Max 140 F)
Connection FL
Dust type Organic
    CARZ US (16'') 400 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73001272

    Diameter (in)
    400
    Length (ft)
    735
    Max explosion pressure (bar)
    0,9
    Weight (lbs)
    126
    CARZ US (6'') 160 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008243

    Diameter (in)
    160
    Weight (lbs)
    51
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    Any
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,4
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,4
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45
    CARZ US (7'') 180 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008244

    Diameter (in)
    180
    Weight (lbs)
    57
    Note
    LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    < LEL
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,9
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,9
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45
    CARZ US (8'') 200 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008245

    Diameter (in)
    200
    Weight (lbs)
    64
    Note
    LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    < LEL
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,9
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,9
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45
    CARZ US (10'') 250 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008238

    Diameter (in)
    250
    Weight (lbs)
    79
    Note
    LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    < LEL
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,9
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,9
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45
    CARZ US (12'') 315 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008239

    Diameter (in)
    315
    Weight (lbs)
    104
    Note
    LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    < LEL
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,9
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,9
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45
    CARZ US (14'') 350 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008240

    Diameter (in)
    350
    Weight (lbs)
    110
    Note
    LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    < LEL
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,9
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,9
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45
    CARZ US (16'') 400 Explosion Isolation Flap Valve FL, Ex D St1

    ArtNo: 73008241

    Diameter (in)
    400
    Weight (lbs)
    126
    Note
    LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
    Explosion Class ATEX
    St1
    Dust Concentration in duct
    < LEL
    Max velocity in duct (m/s)
    30
    Minimum velocity in duct
    0
    Minimum vessel size, push (m3)
    0,9
    Install type
    Push and Pull
    Minimum vessel size, pull (m3)
    0,9
    Kst (bar m/s)
    200
    Maximum reduced pressurem, Pred (bar)
    0,45

Accessories for this product 1

CARZ Locking Sensor set
ArtNo: 73001236

CARZ Locking Sensor set