Explosion Isolation Flap Valve CARZ-N Ø315-1000mm
Explosion Isolation Flap Valve CARZ-N - protective system
Explosion Isolation Flap Valve type CARZ-N prevents a transmission of explosion pressure wave and flames front from the filter to your workplace. By using our CARZ-N Explosion Isolation Flap Valve, you reduce the risk from dust explosion for both people and equipment.FunctionDuring normal operation, the valve is kept open, and large opening angle ensure low pressure drop. In case of an explosion in the filter, the pressure wave will force to close the flap plate and lock in position. When flap plate is closed it makes an effective barrier against approaching flame front. This prevent the explosion from being transmitted from the filter to upstream work areas. No matter what industry you are in or what type of dust is generated in your factory, we can provide the complete dust explosion protection solution of filters, and explosion isolation flap valves.
-
Independently tested to latest and most stringent standards and regulations
-
Compliant with international dust explosion protection codes (ATEX, NFPA69, IECEx)
-
Widest range of sizes, applications and filter system configurations on the market (e.g. approval for positive and negative pressure systems, approval for St2 dusts up to size 630 inclusive)
-
Manufactured fully by Nederman under certified quality assurance system, ensuring highest level of quality and reliability
Certifications |
CE, EX |
Material |
Welded carbon steel, painted RAL5009 |
Operating temperature range |
-20 - +70°C (0 - 160F) |
Ambient temperature range |
-20 - +60°C (0 - 140F) |
Connection |
FL |
Max velocity in duct (m/s) |
30 |
Minimum velocity in duct |
0 |
Install type |
Push and Pull |
CARZ-N US (18'') 450 Explosion Isolation Flap Valve FL, Ex D St2
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
0,9
Dust type
Metallic/Organic
CARZ-N US (20'') 500 Explosion Isolation Flap Valve FL, Ex D St2
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
1,6
CARZ-N US (22'') 560 Explosion Isolation Flap Valve FL, Ex D St1
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
1,6
CARZ-N US (25'') 630 Explosion Isolation Flap Valve FL, Ex D St1
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
1,6
CARZ-N US (28'') 710 Explosion Isolation Flap Valve FL, Ex D St1
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N US (32'') 800 Explosion Isolation Flap Valve FL, Ex D St1
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N US (36'') 900 Explosion Isolation Flap Valve FL, Ex D St1
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N US (40'') 1000 Explosion Isolation Flap Valve FL, Ex D St1
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N 450 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
0,9
Dust type
Metallic/Organic
CARZ-N 500 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
1,6
CARZ-N 560 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
1,6
CARZ-N 630 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
1,6
CARZ-N 710 Explosion Isolation Flap Valve FL, Ex D St1, with dust build-up and flap lock sensor
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N 800 Explosion Isolation Flap Valve FL, Ex D St1, with dust build-up and flap lock sensor
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N 900 Explosion Isolation Flap Valve FL, Ex D St1, with dust build-up and flap lock sensor
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N 1000 Explosion Isolation Flap Valve FL, Ex D St1, with dust build-up and flap lock sensor
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
3,2
Minimum vessel size, pull (m3)
3,2
CARZ-N 315 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Dust Concentration in duct
Any
Minimum vessel size, push (m3)
0,46
Minimum vessel size, pull (m3)
0,46
Dust type
Metallic/Organic
Maximum reduced pressurem, Pred (bar)
0,5
CARZ-N 350 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
0,9
Dust type
Metallic/Organic
CARZ-N 400 Explosion Isolation Flap Valve FL, Ex D St2, with dust build-up and flap lock sensor
Note
LEL = Lower Explosion Limit = MEC Minimum Explosion Concentration
Minimum vessel size, push (m3)
1,6
Minimum vessel size, pull (m3)
0,9
Dust type
Metallic/Organic